A11VO variable piston pump
DEKE
关键词:
Deke specializes in the production of hydraulic oil pumps. Its main products include A2F/A2FE/A2FM series inclined shaft piston pump/motor, A7V inclined shaft piston pump, A6V variable piston motor, A4VSO, A10VSO axial piston pump, and PV2R series high pressure low noise quantitative vane pump;
key word:
Industrial plunger pump | inclined shaft motor | inclined shaft plunger pump
Category:
Description
Deke Hydraulic specializes in the production of hydraulic oil pumps. Its main products include A2F/A2FE/A2FM series inclined shaft piston pump/motor, A7V inclined shaft piston pump, A6V variable piston motor, A4VSO, A10VSO axial piston pump, and PV2R series high pressure low noise quantitative vane pump;
The enterprise has a technical team and hydraulic pump production equipment. The enterprise adheres to the manufacturing concept of "no best, only better", and its continuous research, development and improvement are only for serving your needs. It is widely used in construction machinery, industrial equipment, metallurgical machinery, plastic machinery, walking machinery, forging, machine tools, shipbuilding, medical treatment, etc.
Product Description:
0-A11VO inclined plate structure axial piston variable displacement pump, used for static hydraulic transmission in open circuit hydraulic systems.
The flow rate is proportional to the transmission speed and displacement, and by adjusting the angle of the swashplate, the flow rate can be continuously changed.
Structural features:
Under the condition of pressurizing the fuel tank or using the optional built-in pressurization pump, the axial piston pump can operate in a white oil supply state.
Provide various control devices to meet different application requirements.
Even when the plunger pump is running, the power control device can be adjusted externally.
◆ Through shaft drive is suitable for fitting gear pumps and axial piston pumps of the same specifications.
The output flow rate is proportional to the driving speed and can vary infinitely between qvmax and qvma=0.
Application field:
◆ Construction machinery and light industry equipment
◆ Steel metallurgy and mining machinery
◆ Ship and civil aviation ground equipment
◆ Petroleum and petrochemical machinery
◆ Construction and walking machinery
Model Description

1. Axial plunger element
| Component form/specification: | 40 | 60 | 75 | 95 | 130 | 145 | 190 | 260 | code |
| Variable swash plate structure engineering level | ■ | ■ | ■ | ■ | ■ | ■ | ■ | ■ | A11V |
2、Booster pump
| Booster pump/specifications: | 40 | 60 | 75 | 95 | 130 | 145 | 190 | 260 | code |
| Without a booster pump No code | ◆ | ◆ | ◆ | ◆ | ◆ | ◆ | ■ | ■ | * |
| With booster pump | * | * | * | * | ■ | ■ | ◆ | ◆ | L |
3、Operating mode
| Operating mode/specifications: | 40 | 60 | 75 | 95 | 130 | 145 | 190 | 260 | code |
| Pump open circuit | □ | □ | □ | ■ | ■ | ■ | ■ | □ | O |
4、Component specifications
| Component displacement/specifications: | 40 | 60 | 75 | 95 | 130 | 145 | 190 | 260 | code |
| displacement≌Vgmax(cm3/r) | 40 | 60 | 75 | 95 | 130 | 145 | 190 | 260 | * |
◆=Optimal solution (shorter delivery time)
■=Available for supply
□=In preparation
*=No supply
5. Control device
| Control mechanism/specifications: | 40 | 60 | 75 | 95 | 130 | 145 | 190 | 260 | code | |||||||
| power control | LR | ◆ | ◆ | ◆ | ◆ | ◆ | ◆ | ◆ | ◆ | LR | ||||||
| With unauthorized control | Cross induction | negative electrode LR | C | ■ | ■ | ■ | ■ | ■ | ■ | ■ | ■ | LR.C | ||||
| Related to high pressure | negative electrode LR3 | ■ | ■ | ■ | ■ | ■ | ■ | ■ | ■ | LR3 | ||||||
| Related to pilot pressure | negative electrode LG1 | ■ | ■ | ■ | ■ | ■ | ■ | ■ | ■ | LG1 | ||||||
| positive electrode LG2 | ■ | ■ | ■ | ■ | ■ | ■ | ■ | ■ | LG2 | |||||||
| Electrical U=12V | negative electrode LE1 | 口 | 口 | 口 | ■ | ■ | ■ | ■ | ■ | LE1 | ||||||
| U=24V | negative electrodeLE2 | 口 | ■ | ■ | ■ | ■ | ■ | ■ | ■ | LE2 | ||||||
| Pressure cut-off valve | D | ◆ | ◆ | ◆ | ◆ | ◆ | ◆ | ◆ | ◆ | L.D.. | ||||||
| Hydraulic, Level 2 | E | ■ | ■ | ■ | ■ | ■ | ■ | ■ | ■ | L.E.. | ||||||
| Hydraulic. Remote control | G | ■ | ■ | ■ | ■ | ■ | ■ | ■ | ■ | L..G. | ||||||
| With load sensing | S | ◆ | ◆ | ◆ | ◆ | ◆ | ◆ | ◆ | ◆ | L..S. | ||||||
| Electrical, proportional override control, 24V | S2 | 口 | 口 | 口 | ■ | ■ | ■ | ■ | ■ | L...S2 | ||||||
| Hydraulic. Proportional Overcontrol | S5 | 口 | 口 | 口 | ■ | ■ | ■ | ■ | ■ | L...S5 | ||||||
| With travel limiter | Negative electrode characteristics | ⊿P=25 bar | H1 | ■ | ■ | ■ | ■ | ■ | ■ | ■ | ■ | L...H1 | ||||
| ⊿P=10 bar | H5 | ■ | ■ | ■ | ■ | ■ | ■ | ■ | ■ | L...H5 | ||||||
| Positive electrode characteristics | ⊿P=25 bar | H2 | ◆ | ◆ | ◆ | ◆ | ◆ | ◆ | ◆ | ◆ | L...H2 | |||||
| ⊿P=10 bar | H6 | ■ | ■ | ■ | ■ | ■ | ■ | ■ | ■ | L...H6 | ||||||
| U=12V | U1 | ■ | ■ | ■ | ■ | ■ | ■ | ■ | ■ | L...U1 | ||||||
| U=24V | U2 | ■ | ■ | ■ | ■ | ■ | ■ | ■ | ■ | L..U2 | ||||||
| pressure control | DR | ◆ | ◆ | ◆ | ◆ | ◆ | ◆ | ◆ | ◆ | DR | ||||||
| With load sensing | DRS | ◆ | ◆ | ◆ | ◆ | ◆ | ◆ | ◆ | ◆ | DRS | ||||||
| Remote control | DRG | ■ | ■ | ■ | ■ | ■ | ■ | ■ | ■ | DRG | ||||||
| Used for parallel operations | DRL | ■ | ■ | ■ | ■ | ■ | ■ | ■ | ■ | DRL | ||||||
| Hydraulic control and pilot pressure related | (Positive electrode characteristics) | ⊿P=10 bar | HD1 | ■ | ■ | ■ | ■ | ■ | ■ | ■ | ■ | HD1 | ||||
| ⊿P=25 bar | HD2 | ■ | ■ | ■ | ■ | ■ | ■ | ■ | ■ | HD2 | ||||||
| Pressure cut-off valve | D | ◆ | ◆ | ◆ | ◆ | ◆ | ◆ | ◆ | ◆ | HD.D | ||||||
| With pressure shut-off valve Remote control | G | 口 | ■ | 口 | 口 | 口 | 口 | ■ | ■ | HD.G | ||||||
| Electronic control with proportional electromagnet | Positive electrode characteristics) | U=12V | EP1 | ■ | ■ | ■ | ■ | ■ | ■ | ■ | ■ | EP1 | ||||
| U=24V | EP2 | ■ | ■ | ■ | ■ | ■ | ■ | ■ | ■ | EP2 | ||||||
| Pressure cut-off valve | D | ◆ | ◆ | ◆ | ◆ | ◆ | ◆ | ◆ | ◆ | EP.D | ||||||
| Remote control with pressure cut-off valve two | G | ◆ | ◆ | ◆ | ◆ | ◆ | ◆ | ◆ | ◆ | EP.G | ||||||
Remarks:
In the control with several additional functions, the eye order of the standby column is maintained, and each column can only have one option (e.g. LRDCH2).
For power control, the following combinations are currently not available:
LRDS2,LRDS5,L..GS2,L..GS5,L..EC
And combination L DG along with travel limiters H1, H2, H5, H6, U1, and U2.
6、Structural series:
| Structural series/specifications: | 40 | 60 | 75 | 95 | 130 | 145 | 190 | 260 | code |
| structural series | ■ | ■ | ■ | ■ | ■ | ■ | ■ | ■ | 1 |
7、Index code:
| Index code/specification: | 40 | 60 | 75 | 95 | 130 | 145 | 190 | 260 | code | |
| Index code | specification40...130 | ■ | ■ | ■ | ■ | ■ | * | * | * | 0 |
| specification145...260 | * | * | * | * | * | ■ | ■ | ■ | 1 | |
8、Rotation direction:
| View Discovery/Find Direction: | Rotation direction | code |
| From the end of the shaft | Clockwise (forward to right) | R |
| Counterclockwise (reverse left turn) | L |
9、Component sealing:
| Index code/specification: | 40 | 60 | 75 | 95 | 130 | 145 | 190 | 260 | code |
| NBR (nitrile rubber, according to DIN ISO1629) with FKM (fluororubber) shaft seal | ■ | ■ | ■ | ■ | ■ | ■ | ■ | ■ | N |
10、Component output shaft:
| Output shaft type/specification: | 40 | 60 | 75 | 95 | 130 | 145 | 190 | 260 | code | |
| Spline shaft in accordance with DIN 5480 | Used for single stage pumps and combination pumps | ■ | ■ | ■ | ■ | ■ | ■ | ■ | ■ | Z |
| Flat key shaft in accordance with DIN 6885 | ◆ | ◆ | ◆ | ◆ | ◆ | ◆ | ◆ | ◆ | P | |
| Spline shaft complies with AUSL B92.1a-1976 | Used for single stage pumps | ◆ | ◆ | ◆ | ◆ | ◆ | ◆ | ◆ | ◆ | S |
| Used for single stage pumps | ■ | ■ | ■ | *1) | *1) | *1) | ■ | ■ | T | |
11、mounting flange:
| Flange form/specification: | 40 | 60 | 75 | 95 | 130 | 145 | 190 | 260 | code | |
| Compliant with SAE J744 | 2hole | ◆ | ◆ | ◆ | * | * | * | * | * | C |
| 4hole | * | * | ◆ | ◆ | ◆ | ◆ | ◆ | ◆ | D | |
| Compliant with SAE J6172) | (SAE3) | * | * | * | ■ | ■ | ■ | ■ | * | G |
12、Working oil port:
| Oil port position/specification: | 40 | 60 | 75 | 95 | 130 | 145 | 190 | 260 | code |
| SAE flange, oil ports B and S are located on opposite sides of the rear. Metric fastening thread | ■ | ■ | ■ | ■ | ■ | ■ | ■ | ■ | 12 |